To the analysis database

How PeptiCheck works

PeptiCheck is a collection of lab values for individual submitted samples — not a rating of vendors. Each entry names the lab, date and batch and is tied to the original lab report, which you can verify with the lab yourself. This page explains how an entry comes about and how to read it.

What you'll find here

  • The measured values of a specific sample, with date and batch.
  • The lab report in the original, with the order number so you can check it yourself.
  • Averages and trends per vendor — as numbers, not as a verdict.
  • Fixed thresholds that every sample is held against.

What you won't find here

  • No grades, stars, points or rankings.
  • No recommendation on who to buy from.
  • No sources, contact details or prices.
  • No dosing or usage advice.

The reason for this separation isn't reticence, but the difference between a fact and an opinion: "This sample has 99.2% purity" can be verified, "this vendor is good" can't. That's why every sample is held against the same fixed rule and never against another sample. If you think the threshold is wrong, you can read it up and put the raw values in context yourself.

A sample's journey

  1. 1Someone submits a sample — A member registers a sample: substance, vendor, declared amount, batch, purchase date. Who can do this depends on trust level — every submission costs us lab fees and shipping.
  2. 2The origin is verified — No proof, no entry. Purchase receipt, proof of payment and a photo of the unopened vial with the batch label stay private with the editorial team; later, only a note that they exist is made public.
  3. 3We commission the lab — The order goes through us, so queries and order numbers don't end up with the submitter. They send the sample to the lab themselves — we never touch a substance.
  4. 4The lab measures and reports — Each commissioned test comes back with its own report and its own order number. Four tests mean four pieces of evidence, not one document.
  5. 5We enter and publish — The measured values go from the report into the table, and the report itself sits alongside. An entry can't be published at all without at least one report.

Origin is a condition for release, not an extra. Nothing is published without complete proof — a measurement without documented origin is just a claim about a vendor. Purchase receipt and proof of payment are deleted after publication; what stays visible is the vial photo and the note "PeptiChat holds proof of origin".

What each test proves

A lab only tests what was commissioned. That's why every row of the measurement table shows which report supports it — and why criteria that weren't commissioned stay empty.

  • HPLCproves Purity and AmountSeparates the product into its components and measures how much of each is in it. This shows how pure the substance is and whether the amount matches the declaration.
  • LC-MSproves IdentityWeighs masses and so proves which substance is actually in the vial. This is the test that exposes a mix-up or a different compound.
  • Endotoxin testproves EndotoxinsMeasures bacterial breakdown products. A separate test with its own report — a purity measurement tells you nothing about it.
  • Heavy metal testproves Heavy metalsLooks for residues from manufacturing and packaging. Also a separate test with its own report.

A purity measurement is not proof of identity. It tells you how cleanly things were separated — not which substance is there. A check mark appears next to "Identity" only when a report also measured by mass spectrometry. Many standard reports include both; then one document supports both rows.

What we measure against

The thresholds are fixed and public. They're the difference between a rule and a hidden judgement: every sample is held against the same number.

  • Purity — at least 99.00 %.
  • Identity — active ingredient detectable in the product.
  • Amount — within ±5 % of the declared amount.
  • Endotoxins — whole vial under 350 EU (5 EU/kg × 70 kg, USP <85>).
  • Heavy metals — lab report without objections.
  • Criteria that weren't checked stay empty — that's not a fail.

The endotoxin threshold comes from the pharmacopoeia (USP <85>), not from the lab: the lab measures and prints the value but doesn't rate it. The calculation deliberately uses the entire vial contents at once — if that stays below the limit, any partial amount does too, however someone proceeds. Conversely, "failed" doesn't mean "dangerous", but "the pharmacopoeial threshold would be exceeded at full vial amount".

You don't have to take our word for it

Every report shows the lab's order number and, where the lab offers a verification page, a link to it. That lets you check every value directly with the lab, without us. That's exactly what the number is for — a database you can only trust us on would be worthless.

How to spot a forged report is also shown by the Certificate checker.

What's free — and what membership covers

Always free

  • Failed analyses in full — including vendor and all values. A contamination, a missing active ingredient or a severe underdose is a health warning, and that never sits behind a paywall.
  • Warnings about specific scams, across the whole forum.
  • This page, the test thresholds and the rules.

For members

  • Vendor name and measured values of passed analyses.
  • The averages per vendor and the vendor overview.
  • The discussion threads about the vendors.

So far, the platform pays the lab fees. What that costs and how you can help is explained on the Premium page.

What we explicitly don't do

  • No vendor-paid tests. Whoever pays chooses the sample — meaning their best batch. The result would be worthless, and it would devalue exactly what this is all about. Any vendor can respond to a result; they can't buy a test.
  • We never touch any substance. We don't buy anything, ship anything or broker anything. The sample goes from the sender directly to the lab.
  • No sources. Who gets talked about is up to the members — how to reach them is never stated here, and the filter removes it from posts as well.

This lab result applies only to the submitted sample. It says nothing about other batches, later deliveries or the vendor's other products.