HPLC Purity of Peptides: What 98% Really Means

In shortHPLC measures what share of the total signal in a sample comes from the target peptide. 98% means: 98% of the detected peak area belongs to the main peak. This value says nothing about the identity of the peptide, endotoxins, heavy metals or the content per vial.

"98% purity" is the number almost everyone looks at when it comes to peptides. It usually comes from an HPLC measurement. The number is not wrong, but it answers a much narrower question than many people think. In this guide we explain what HPLC measures, how it differs from mass spectrometry, whether 98% is enough and which tests a purity value does not replace. We do not recommend any laboratory or supplier.

Education & information only — no medical advice, no instructions for use/dosing. Copying anything is at your own risk (18+). Details in the disclaimer.

What does HPLC measure?

HPLC stands for high-performance liquid chromatography. The dissolved sample is pumped through a separation column. Different components travel at different speeds and therefore reach the detector, usually a UV detector, at different times. The result is a chromatogram: a curve with individual spikes, the peaks.

Purity is calculated from the area under these peaks (peak area). The area of the main peak is divided by the area of all detected peaks. Purity is therefore a relative value. It tells you what share the main product makes up of everything the method detects and separates from each other.

According to the specialist literature, typical impurities in synthetic peptides are chains with missing or additional amino acids, truncated chains, residues of protecting groups from the synthesis, oxidised variants and stereoisomers, i.e. molecules in which one amino acid has been incorporated in its mirror-image form. In the best case, such by-products appear as small peaks of their own next to the main peak.

In the best case, because not every impurity is cleanly separated. In its guideline on synthetic peptides, the EMA explicitly points to the risk that impurities leave the column together with the main peak (co-elution). They are then hidden within the main peak and raise the purity value instead of lowering it. How meaningful a purity figure is therefore always depends on how well the method is suited to that particular peptide.

HPLC or mass spectrometry: what is the difference?

HPLC separates and measures proportions. But it does not tell you what the main peak is. A wrong peptide can produce a nice, large main peak just as well as the right one.

Mass spectrometry (MS), by contrast, measures the mass of the molecules. If the measured mass matches the calculated mass of the peptide, that is a strong indication of the correct identity. According to the EMA guideline, certain variants of MS can also confirm the sequence of amino acids. The two methods are often coupled (LC-MS, liquid chromatography–mass spectrometry): HPLC separates, MS determines what is behind the main peak and the secondary peaks.

MS also has limits. On its own it cannot distinguish molecules of the same mass, such as stereoisomers. For medicinal products, the EMA therefore recommends confirming the identity of a peptide with at least two mutually independent methods. The ICH Q2(R2) guideline describes the same principle in general terms: if a method is not specific enough, another method should compensate. And MS is primarily proof of identity, not proof of quantity.

For you, this means: a CoA that only states an HPLC purity does not answer the question "Is it the right peptide?". Only proof of identity by MS, ideally with the measured mass stated, makes the purity figure meaningful at all.

Is a purity of 98% enough?

There is no blanket threshold above which a peptide is "safe". What matters is not only how large the remainder is, but what it consists of. A 2% remainder can be harmless degradation products or a single impurity that has never been investigated.

The EMA guideline shows how strictly this is viewed for medicinal products. It refers to thresholds of the European Pharmacopoeia (Ph. Eur.) for peptide-related impurities: from 0.1%, an impurity must be reported, from 0.5% identified, and from 1.0% its safety must be demonstrated in preclinical studies. For an authorised peptide, a remainder of 2% would therefore not be left as a single figure but broken down into individual, named impurities with their own limits.

A CoA that only states "Purity 98%" tells you nothing about this. You do not know whether the remainder consists of one large secondary peak or many small ones, nor what those peaks are. It is therefore helpful if the chromatogram is supplied and the secondary peaks are listed individually.

In addition, the value depends on the method. A method that does not separate certain impurities from the main peak measures a higher purity than one that does. Two purity values from different laboratories or under different conditions are therefore only comparable to a limited extent.

What does HPLC not test?

For synthetic peptides, the EMA lists a whole series of tests that are needed in addition to purity. None of them is covered by an HPLC purity value:

  • Identity: whether the main peak is the right peptide. This requires MS or other methods, see above.
  • Content per vial: How many milligrams of peptide are actually in it is a separate measurement against a reference standard. According to the EMA, this content is stated without counterions and water, because a lyophilisate contains both.
  • Water, counterions and residual solvents: Synthetic peptides are usually present as a salt, for example with acetate or trifluoroacetate (TFA). The EMA guideline addresses each of these components separately.
  • Endotoxins: components of the cell wall of certain bacteria that can trigger fever and inflammatory reactions. They are measured with the LAL test, not with HPLC.
  • Heavy metals (elemental impurities): For medicinal products, the ICH Q3D guideline regulates which elements are permitted up to which amount. They are measured with separate methods.
  • Microbiological purity and sterility: whether germs are present in the sample.

A practical example: high claim, completely different result

A study in the Journal of Medical Internet Research (2024) shows how far claim and measurement can diverge. Researchers tried to obtain semaglutide online without a prescription. Of six attempts, only three vials arrived. A purity of 99% was advertised. Measured by LC-MS, the figures were 7.7 to 14.4%. At the same time, the measured content was 29 to 39% above the printed amount, and endotoxins were found in all three samples, even though no live germs were detectable.

The example shows all the points of this guide at once: the advertised purity was not correct, purity and content were two completely different questions, and no purity measurement would have found the endotoxins.

How does a laboratory report differ from a supplier CoA?

A CoA issued by the supplier or its manufacturer itself is a self-declaration. You can usually not verify whether the number is correct, whether it belongs to your batch and which method it was obtained with.

A test report from an independent laboratory is something different: the laboratory has no interest of its own in the result, states the method and the sample, and can often be verified directly. Accreditation under DIN EN ISO/IEC 17025 shows whether a laboratory works according to the requirements for testing laboratories. In Germany it is awarded by the German Accreditation Body (Deutsche Akkreditierungsstelle, DAkkS), which lists the accredited bodies in a public database. However, accreditation applies to specific procedures, not automatically to every analysis a laboratory performs.

Even an independent report only applies to the sample that was submitted. It is a snapshot, not a guarantee for other vials or batches. And it does not replace manufacture to medicinal-product standards. A laboratory test is not a clearance for use.

How to read a certificate as a whole, i.e. laboratory, batch number, date and typical forgeries, is explained in our guide "Reading a CoA".

Frequently asked questions

What does HPLC purity of 98% mean?

That 98% of the detected peak area in the chromatogram belongs to the main peak. This is a relative value. It says nothing about whether the main peak is the right peptide, how many milligrams are in the vial or whether endotoxins are present.

Is 99% better than 98%?

Not necessarily. Both values are only comparable if they were measured with the same, suitable method. More important than one percentage point is what the remainder consists of and whether the identity was confirmed by mass spectrometry.

What is the difference between HPLC and LC-MS?

HPLC separates the sample and measures proportions. In LC-MS, a mass spectrometer is additionally connected, which determines the mass of the molecules. This makes it possible to check whether the main peak is the expected peptide.

Does HPLC detect endotoxins or heavy metals?

No. Endotoxins are measured with the LAL test, heavy metals with separate methods. A certificate only says something about this if these tests are listed explicitly.

Does a good laboratory result mean I can use the peptide?

No. A laboratory test is not a clearance for use. It describes a sample at one point in time, and does not replace manufacture to medicinal-product standards or medical advice.

Sources

  1. EMA — Guideline on the development and manufacture of synthetic peptides (EMA/CHMP/CVMP/QWP/367182/2025), effective from 01/06/2026.
  2. ICH Q2(R2) — Validation of Analytical Procedures (2023): specificity and supplementary methods.
  3. D'Hondt M et al. — Related impurities in peptide medicines. J Pharm Biomed Anal 2014;101:2–30.
  4. Ashraf AR et al. — Multifactor Quality and Safety Analysis of Semaglutide Products Sold by Online Sellers Without a Prescription. J Med Internet Res 2024 (PMC11582493).
  5. FDA — Guidance for Industry: Pyrogen and Endotoxins Testing: Questions and Answers (USP <85>, LAL test).
  6. EMA — ICH Q3D Elemental impurities (R2).
  7. DAkkS — Testing and calibration laboratories according to DIN EN ISO/IEC 17025, database of accredited bodies.
Checked against primary sources — no forum content as a source. No dosing or usage instructions. How we check.